Historial de Commits

Autor SHA1 Mensaje Fecha
  Fernando Pablo Lopez-Lezcano 604984fbd6 in TinySpHEAR go back to 1mm walls, 2 * that creates trouble printing, the material gets too hot because of the printing pattern and the shape is rough and bumpy, also remove the intermediate flare - we do not really need that for now hace 10 años
  Fernando Pablo Lopez-Lezcano 9468249d5e properly join the flares with the mount stalks introducing mint_thin slices for the hulls, make the wall of the flare constant thickness, make stalk the same thickness as the flare, add an additional transition between flare and stalk, add transition in the lip to avoid overhangs while printing, replace top ellipsoid microphone array mount in TinySpHEAR with a rounded box which gives better cable clearance hace 10 años
  Fernando Pablo Lopez-Lezcano 47d8438cfd remove ring_arm_gap as it is a global, reorder some parameters for clarity hace 10 años
  Fernando Pablo Lopez-Lezcano 80d3885a52 move eyelet of shock mount from TinySpHEAR and Octathingy to SpHEAR_common, rework rendering of full shock mount hace 10 años
  Fernando Pablo Lopez-Lezcano 43884ed6c0 move stand mount of shock mount from TinySpHEAR and Octathingy to SpHEAR_common hace 10 años
  Fernando Pablo Lopez-Lezcano 066c4aa3d8 move ring connectors of shock mount from TinySpHEAR and Octathingy to SpHEAR_common hace 10 años
  Fernando Pablo Lopez-Lezcano 7b08ce8c2e move external ring of shock mount from TinySpHEAR and Octathingy to SpHEAR_common hace 10 años
  Fernando Pablo Lopez-Lezcano 46c54db512 move internal ring of shock mount from TinySpHEAR and Octathingy to SpHEAR_common hace 10 años
  Fernando Pablo Lopez-Lezcano f4fd8cceda move shared modules to SpHEAR_common, remove from TinySpHEAR and Octathingy mount_pcb files, change the names of some modules for readability hace 10 años
  Fernando Pablo Lopez-Lezcano 2b2cbfbbd5 a couple of tweaks for better fit after printed hace 10 años
  Fernando Pablo Lopez-Lezcano 85ad463b8c tweak some tolerances for altest test print, calculate mount corner automatically hace 10 años
  Fernando Pablo Lopez-Lezcano ecfb059220 change pcb dimensions and tolerances, adjust parameters for ccrma logo hace 10 años
  Fernando Pablo Lopez-Lezcano 6e48003c29 change length and width of pcb to match new design, parametrize several hard coded numbers, add space in front of and behind the printed circuit board, make main body more rounded, remove old version of main body, add dot in the microphone stalk marking the back of the microphone, add CCRMA logo to microphone body hace 10 años
  Fernando Pablo Lopez-Lezcano 3f6a270667 really push changes to TinySpHEAR_common.scad, TinySpHEAR_mount_pcb.scad and TinySphEAR.scad hace 10 años
  Fernando Pablo Lopez-Lezcano 38f7c51b4c add proper fit to radius of top conic section hace 10 años
  Fernando Pablo Lopez-Lezcano 92a7090ff8 another design for the outer ring of the shock mount hace 10 años
  Fernando Pablo Lopez-Lezcano 87283f487e add mount hub for shock mount hace 10 años
  Fernando Pablo Lopez-Lezcano c243c595ca more improvements to inner rings of shock mount - add rounded corners in rubber band slots, make connecting bars fit with slots, add triangular fillet around bar holes hace 10 años
  Fernando Pablo Lopez-Lezcano 519d7fd4f8 new version of body with just one slot at the bottom to make space for shielding the printed circuit boards; more work on the shock mount for the microphone assembly hace 10 años
  Fernando Pablo Lopez-Lezcano e2c2a4ffd4 fix the rounded corners of all boxes so that the wall is constant thickness, create another function for the support ring of the shock mount, calculate radius of support ring based on the approximate angle of the elastic bands and the separation between the body rings hace 10 años
  Fernando Pablo Lopez-Lezcano 6f79316ce3 start work on a shock mount for the whole microphone assembly (the microphone sits on the shock mount) hace 10 años
  Fernando Pablo Lopez-Lezcano e75115f167 render capsules with more facets, tune some fits for new printer, add one more parameter to capsule code to better fit the mount slots to the capsule array, actually fix the sign of the previous fit parameter (was making things smaller, not bigger), modify calls to do the right thing hace 10 años
  Fernando Pablo Lopez-Lezcano 98d24b539d add rfit parameter to the capsule module, this is needed so that carving the slots for the conical section of the mount works better; also adjusted the radius of the conical section of the mount so that it fits the capsule array - the code there is probably not correct and needs to be revised hace 10 años
  Fernando Pablo Lopez-Lezcano 71b503fac6 add a couple more parameters, first try at ccrma logo hace 10 años
  Fernando Pablo Lopez-Lezcano f28732e7ef first try at including the microphone array in the complete design, include common scad file hace 10 años
  Fernando Pablo Lopez-Lezcano e4aa923e74 first iteration of a mount that holds four interface printed circuit boards hace 10 años