Fernando Pablo Lopez-Lezcano
|
55a5b04d21
remove the special case for A2B matrix calculation from the code
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
5adc6de099
remove special case for A2B matrix calculation, normalize second order components of matrix separately
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
7d6a375a47
merge second order code into A2B_matrix
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
692746f61d
add function to measure signal arrival times to all capsules
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
08f2da9b88
add function to plot A format signal power
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
db7e551533
add code to plot high frequency correction filters
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
1c9724a58e
add modified version of Aaron Heller's A2B code to support second order horizontal calibration
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
5771a79b3c
add orientation of generated cardioid or second order lobe
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
873d7dc0d8
add preliminary support for Octathingy calibration and second order horizontal Ambisonics
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
9af24bb643
update design example with Octathingy specific code, add first version of code that tries to measure the z axis wobble during the calibration measurements (with the goal of fixing it)
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
e07c9113e3
transform FIR filters into proper minimum phase filters, add support for second order horizontal components and preliminary low frequency gain limiting of the second order filters
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
b0002c5ecd
add preliminary support for WXYZUV to the A to B encoder Faust code
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
0b92fe5b4f
old updates to the fir filter shape extraction function
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
26af985aef
small changes to support Octathingy calibration and second order horizontal Ambisonics
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
6790618c6f
add minimum phase functions (mps.m, fold.m, clipdb.m) from Julius Smith's "Introduction to Digital Filters"
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
69673fa399
push the latest Octathingy_EM200, the code needs to be cleaned up and it is a mess but at least all elements are there
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
dab0d59629
add new windscreen rendering code to TinySpHEAR_EM200, remove old bottom capsule render line
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
1245a430da
add windscreen rendering code to TinySpHEAR_EM182
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
d50b3afe53
remove bottom capsule from the TinySpHEAR_EM182 file as we are not using that anymore - we have to clean up the rest of the files as well
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
90b5eadd79
add a design example that outlines the process of designing a simple A to B encoder
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
2aaf418ea6
add common short support functions for calibration, load before starting the process
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
098f0fbd19
add a bunch of support functions for new encoder design process
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
adb683e3e1
change default location of calibration file in drc configuration file
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
84690fcce7
add reference microphone argument to reference filter calculation, other small fixes
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
9abf720efa
label B-format plot properly if the Z component is replaced by a virtual cardioid
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
a6af3baf22
add FOA support code for the Octathingy, assumes the up/down orientation of the capsules follows the recommended build, uses pseudo inverse for Octathingy as system is overspecified
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
8389cd8cc8
add Octathingy direct mount to quik release stand (rigid instead of shock mount), useful for calibration
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
777beabdae
much better design for connector from microphone mount to microphone stand, add one version with threaded bottom in addition to the one for quik-release mount
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
073157dec3
final TinySpHEAR 12 pin DIN connector wiring
|
9 tahun lalu |
Fernando Pablo Lopez-Lezcano
|
257598d051
final Octathingy DB25 connector wiring
|
9 tahun lalu |