Histórico de Commits

Autor SHA1 Mensagem Data
  Fernando Pablo Lopez-Lezcano a37acc2223 zapnspark: change R2/R5 to current 2.21K value há 8 anos atrás
  Fernando Pablo Lopez-Lezcano c679a99d39 zapnspark: move traces in PCB to the right layer (back), remove extra components from parts list há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 2b6253bfd0 sphear_plot_directions: remove old code, clean up, add support for Octathingy (but not yet for UV) há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 63f482be52 calibration common code: changes names of files to account for new Aliki, add some support for experimenting with array of filters for U/V instead of single filters like for WXYZ há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 5e0530b8fb write encoder: add parameter for encoder name, make code compatible with both original Faust and Faust 2 há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 2b299d9204 sphear_octa_af_calibrate: change code to use latest aliki from Fons that can handle 8 capsule microphones há 8 anos atrás
  Fernando Pablo Lopez-Lezcano f69dd3d9ae sphear_design_fir_filters: remove leftover comment há 8 anos atrás
  Fernando Pablo Lopez-Lezcano b620c63117 sphear_design_fir_filters: fix n-1 mistake when making filters, fix linear phase code to match, remove old code há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 208f4eae69 return cable holes to original orientation (after some tests with alternative connections from stalk to capsule array) há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 6d3fdddd9c Octathingy: rework capsule mount flare to have more open spaces, add rendering of new dsub connector flare, add walls to shock mount inner ring so columns cannot flex há 8 anos atrás
  Fernando Pablo Lopez-Lezcano e786aad467 Octathingy calibration: fix normalization of A2B matrix, the UV components were being boosted so signals close to full scale were being clipped, and then attenuated by the filters há 8 anos atrás
  Fernando Pablo Lopez-Lezcano 9ec3c9d98b add shock mount stops in Octathingy, rotate "front of microphone" mark há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 9be86c043e remove TinySpHEAR code (four capsule microphone) for old shock mount (internal ring, external ring and connecting rods), add ridges and channels to guide rubber bands in internal ring, connect internal ring columns with walls so they cannot bend, add parameters for new shock mount, redo rendering code for the different parts, update EM182 and EM200 versions of the microphone to render the new shock mount há 9 anos atrás
  Fernando Pablo Lopez-Lezcano c37ffbf9c5 add stop/support for shock mount to upper flare of tetra mic, first version of new external ring for shock mount há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 79e4376888 start design of new version of tetra mic shock mount based on the mount shock for the Octathingy há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 56b4924ba9 remove temporary TFIR return parameter, some changes to parameters to function há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 3945776c56 add more generic sphear_signal_plot_frequency_response, modify design example to use it há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 45f8d24f62 rename some parameters há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 199950be06 move 2nd order lobe to be an option to the standard cardioid override há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 86aab2364e fix A2B_matrix to work with tetrahedral data again há 9 anos atrás
  Fernando Pablo Lopez-Lezcano a66b73b38d many small changes to match the new arguments of B format plotting function há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 014ceb867e remove unused plotting code, scale all plots so that 0 dB is relative to W signal power at a reference frequency range, add optional title argument há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 5bf4006c2c use size of B components to decide whether to calculate UV há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 18195487df sync example with fixes in filter shape extraction há 9 anos atrás
  Fernando Pablo Lopez-Lezcano ab544f172b try to optimize which directions to use for extracting the filter shapes from the B format power frequency response (not very clear for the 8 capsule array) há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 55a5b04d21 remove the special case for A2B matrix calculation from the code há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 5adc6de099 remove special case for A2B matrix calculation, normalize second order components of matrix separately há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 7d6a375a47 merge second order code into A2B_matrix há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 692746f61d add function to measure signal arrival times to all capsules há 9 anos atrás
  Fernando Pablo Lopez-Lezcano 08f2da9b88 add function to plot A format signal power há 9 anos atrás